Office area

Substructure

Pre-stressed concrete piles.

Floor

Reinforced concrete slab or precast concrete slab (300-500 kg/sqm) with vinyl tile finish.

Walls

Concrete block walls with plaster and paint finish.

Doors and windows

Glass panel with aluminium frame doors and windows for exterior.

Ceiling

Gypsum board with T-bars.

Lighting fixtures

Recessed ceiling mounted lighting fixtures with fluorescent lamps or LED.

External

Road

Reinforced concrete road

Storm drainage

Reinforced concrete pipes with manholes and inspection pit.

Sewage system

PVC pipes with manholes and inspection pit.

Fence

Industrial estate standard (2 metres high).

Gate

Sliding steel gate ( 6 - 10 metres wide).

Guard house

Reinforced concrete structure guard house.

Rental enquiry